MARPOL Annex VI Regulation 16.9 and the 2014 IMO Standard Specification for Shipboard Incinerators (Resolution MEPC.244(66), which replaced MEPC.76(40) as amended by MEPC.93(45)) set the temperature rules. A continuous-feed incinerator may only take waste once the gas leaving its combustion chamber is at 850 °C or hotter. A batch-loaded unit must be built to hit 600 °C in under 5 minutes from start-up and then hold at 850 °C or more (MEPC.244(66) Section 4.1 gives 850 °C to 1,200 °C as the working range for the chamber outlet gas).
Most engine-room incinerator flameouts, refractory spalling failures and back-puffing incidents stem from inadequate free-water decanting in the sludge settling and service tanks before heating, fouled rotary-cup or compressed-air sludge atomisers, soot-coated optical flame-eye scanners, choked uptake spark arresters causing loss of furnace negative pressure, or bypassed safety interlocks.
Under IMO Resolution A.1206(34), Port State Control looks at a short list for incinerators: the unit matches its IMO Type Approval Certificate, the maker's operating manual is on board, the combustion chamber outlet temperature is watched at all times, and sludge is not burned in boilers while in port. Good preparation goes further: prove the MEPC.244(66) safety trips yourself, namely fuel cut within 4 seconds of losing the flame (Section 5.3.2.2), an ignition attempt that gives up after 10 seconds at most (Section 5.3.2.3), the draught switch that stops the burner before the furnace reaches atmospheric pressure (Section 5.3.1.3), the flue-gas and chamber over-temperature cut-outs (Sections 5.3.1.1 and 5.3.1.2), and the door locks that stay on while burning and until the furnace is below 220 °C (Sections 3.10.2 and 3.12).
Flame-failure shutdown within 4 seconds during sludge firing or unstable pulsing flame
Optical flame-eye scanner, sludge metering pump and atomiser (MEPC.244(66) 5.3.2.2)
Free water slugs in un-decanted waste oil flashing into steam and extinguishing the flame, soot-fouled UV or IR scanner lens, choked sludge strainer, or worn atomising air nozzle / rotary cup
Stop sludge feed, drain free water from the incinerator waste-oil service tank until clean oil runs at the sample cock, clean the flame-scanner quartz lens and cooling-air port, inspect the sludge nozzle or rotary cup per the incinerator maker's manual, and restart on distillate pre-heat
Auxiliary distillate pilot burner locks out after max 10-second ignition trial on start-up
Pilot ignition transformer, electrodes and distillate solenoid train (MEPC.244(66) 5.3.2.3)
Carbon-bridged or mis-gapped ignition electrodes, air-locked distillate supply line, seized fuel solenoid valve, or incomplete pre-purge air flow
Allow the full pre-purge fan cycle to clear unburnt vapours before re-attempting ignition, isolate power and check electrode condition and gap against the incinerator maker's manual, bleed air from the distillate filter, and prove solenoid tight shut-off
Furnace negative-pressure alarm and immediate burner circuit trip
Induced-draught flue fan, barometric damper and negative-pressure switch (MEPC.244(66) 5.3.1.3)
Soot-plugged flue-gas uptake or spark arrester, slipped or sheared induced-draught fan belt, seized air-dilution damper, or condensate-blocked pressure-sensing impulse tube
Never wedge or bridge the negative-draught switch. Allow post-purge cooling to finish, blow clear the pressure switch sensing tube, inspect induced-draught fan rotation and dampers, and clean soot from flue uptakes and spark arresters under a cold permit
Waste-oil feed valve refuses to open despite auxiliary burner firing
850 °C minimum combustion chamber gas outlet interlock (MARPOL Annex VI Reg. 16.9)
Combustion chamber outlet thermocouple reading below 850 °C due to excessive dilution air, degraded thermocouple sheath, or insufficient distillate pre-heat time
Check combustion chamber gas outlet temperature display against the 850 °C continuous-feed threshold, inspect thermocouple insertion and cold-junction wiring, verify primary/secondary damper positions per the maker's manual, and never lower the 850 °C controller setpoint
High flue-gas duct temperature (5.3.1.1) or high combustion chamber temperature (5.3.1.2) burner shutdown
Excessive calorific sludge feed rate, oily rags or high-energy waste overloaded in batch chamber driving chamber outlet past the 1,200 °C Section 4.1 ceiling, failed cooling/dilution air fan, or refractory collapse
Keep induced-draught cooling fan running through full post-purge cool-down so refractory cools gradually without thermal shock, verify sludge metering pump speed and dilution damper actuator per the maker's manual, and inspect refractory lining below 220 °C
Charging door or ash-removal door electro-mechanical lock will not release after shutdown
220 °C cooling interlock (MEPC.244(66) Sections 3.10.2 & 3.12)
Furnace or door-zone temperature still above 220 °C during post-purge cooling, defective door thermocouple, or lost control voltage to the solenoid latch
Never force mechanical door overrides while the chamber exceeds 220 °C (preventing flashback and severe burns). Let the cooling fan bring temperatures safely below 220 °C before inspecting the latch solenoid and temperature switch
1. MARPOL Annex VI Regulation 16 Type Approval, Prohibited Wastes & MEPC.244(66) Scope
MARPOL Annex VI Regulation 16 sets the international rules for burning waste on board (the revised Annex VI adopted by IMO Resolution MEPC.176(58), with later amendments). Regulation 16.6.1 says that any incinerator fitted on a ship built on or after 1 January 2000, or put on board any ship on or after that date, needs an IMO Type Approval Certificate. The certificate is listed in Section 2.5 of the Supplement to the International Air Pollution Prevention (IAPP) Certificate and shows the unit meets the IMO standard specification: MEPC.76(40) as amended by MEPC.93(45) for older approvals, or the 2014 specification in MEPC.244(66) for newer units up to 4,000 kW. Regulations 16.7 and 16.8 add that the maker's operating manual must be kept on board and that the people who run the incinerator must be trained to follow it.
Before any bag goes through the charging door or any waste oil is pumped to the incinerator service tank, check it against the bans in Regulations 16.2 and 16.3. Regulation 16.2 rules out burning residues of Annex I, II or III cargoes and the packing they contaminated, PCBs, Annex V garbage with heavy metals beyond trace amounts, refined petroleum products containing halogen compounds, sewage sludge or sludge oil that was not produced on this ship, and exhaust gas cleaning system (scrubber) residues. Under Regulation 16.3, polyvinyl chlorides (PVCs) may only be burned in an incinerator that holds an IMO Type Approval Certificate.
Regulation 16.4 covers burning sludge somewhere other than the incinerator. Sewage sludge and sludge oil made on board during normal running may be burned in boilers or in the ship's main or auxiliary power plant, but not inside ports, harbours or estuaries. Regulation 16.4 does not stop a type-approved incinerator being used in port. Port and coastal States can set their own air-quality limits, though, and some restrict incinerator use in port. Good practice is to check the local port rules with the agent and the bridge team before arrival, and to secure the incinerator if the port does not allow it.
Confirm the incinerator holds an IMO Type Approval Certificate (MEPC.244(66) or MEPC.76(40) as applicable) that matches the entry in Section 2.5 of the IAPP Certificate Supplement. Only a type-approved incinerator may burn PVCs (MARPOL Annex VI Reg. 16.3 & 16.6.1).
Confirm the incinerator maker's operating manual is posted or stowed at the local control panel and responsible engineers hold documented familiarisation records (Reg. 16.7 & 16.8).
Segregate and ban all prohibited wastes: Annex I/II/III cargo residues, PCBs, heavy-metal garbage, halogenated oils, off-ship sludge, and EGCS scrubber residues (Reg. 16.2).
Never burn sludge in boilers or the power plant inside a port, harbour or estuary (Reg. 16.4), and before arrival check the local port and coastal State rules on incinerator use with the agent and bridge team (good practice, as MARPOL itself does not ban a type-approved incinerator in port).
2. Waste-Oil Settling, Free-Water Decanting, Sludge Homogenisation & Heating Control
Unconditioned purifier sludge and machinery-space waste oil frequently contain high and uneven pockets of emulsified or free water alongside dense asphaltene solids. If a slug of free water reaches an 850 °C combustion chamber, instant steam expansion extinguishes the flame within milliseconds, trips the 4-second flame safeguard, thermally shocks hot castable refractory bricks, and leaves unburnt oil mist inside the chamber.
Reliable sludge burning starts in the sludge collecting tank and the dedicated incinerator waste-oil settling/service tank. Never introduce volatile cleaning solvents or low-flashpoint slops below the 60 °C closed-cup flashpoint threshold (SOLAS Regulation II-2/4.2.1.1) into machinery-space waste-oil tanks. Transfer sludge into the incinerator service tank early enough for gravity settling at the moderate conditioning temperature specified in the incinerator maker's manual, then manually drain separated water back to the bilge holding tank via the spring-loaded self-closing drain valve before starting the circulating/mixing loop. Avoid overheating water-laden waste oil close to 100 °C in vented atmospheric tanks, where water boil-over (frothing) pushes hot sludge through tank vents and save-alls.
Once free water has been drained until steady oil appears at the test cock, start the sludge circulating pump or tank homogeniser/comminuter loop and bring the conditioned sludge to the atomising viscosity temperature specified in the incinerator maker's manual. At the end of every sludge-burning cycle, switch the 3-way flushing valve to clean distillate fuel or run the built-in air/steam purge sequence per the maker's manual so viscous sludge does not solidify inside the metering pump, trace-heated delivery pipes or burner lance while the unit stands idle.
Settle waste oil in the incinerator service tank, exclude any low-flashpoint solvents below 60 °C (SOLAS II-2/4.2.1.1), and drain free water via the self-closing bottom drain valve before starting tank circulation or high-stage heating.
Keep waste-oil tank heating strictly within the incinerator maker's temperature band to prevent water boil-over and vapour venting.
Inspect and clean duplex sludge suction strainers and verify dosing/metering pump pressure stability before enabling automatic waste-oil feed.
Flush the sludge dosing pump and burner lance with clean distillate or maker-specified purge air at the end of every firing cycle to prevent carbonised nozzle blockages.
MARPOL Annex VI Regulation 16.9 and MEPC.244(66) Sections 4.1 and 4.2 require the temperature of the gas leaving the combustion chamber to be watched at all times. A continuous-feed incinerator must not take any waste until that temperature reaches 850 °C. A batch-loaded incinerator must be built so the chamber hits 600 °C in under 5 minutes from start-up and then holds at 850 °C or above. Section 4.1 sets a working range of 850 °C to 1,200 °C for the chamber outlet gas, and Section 4.7 asks for the flue gas to be cooled quickly to 350 °C or less within 2.5 m. Together these keep soot and dioxin formation down.
During cold start-up (especially after refractory repairs or long idle periods), bring the primary distillate burner online cleanly and allow the refractory lining to soak up heat gradually. If refractory bricks have absorbed moisture in humid engine rooms, follow the incinerator maker's slow dry-out curve rather than driving straight to maximum firing rate, which turns trapped moisture into steam and spalls refractory faces.
Once the combustion chamber gas outlet thermocouple exceeds 850 °C and releases the waste-oil feed interlock, watch flame colour, furnace sight-glass clarity and uptake smoke. A crisp, bright yellow-orange flame without dark spark trails indicates fine atomisation and balanced primary/secondary air. Heavy black smoke, dripping oil on the hearth floor or carbon stalagmites around the burner cone point to low atomising compressed-air pressure, worn rotary-cup bearings, a partially choked sludge orifice, or sludge viscosity too high from under-heating.
Verify the waste-oil feed solenoid and metering pump remain electrically inhibited whenever combustion chamber gas outlet temperature reads below 850 °C (MARPOL Annex VI Reg. 16.9).
Follow the incinerator maker's slow refractory dry-out routine after cold layups or brickwork repairs to prevent thermal spalling.
Verify atomising air pressure (or rotary-cup drive belt tension and speed) and clean burner tips/cups at the interval in the maker's manual.
Inspect combustion chamber and flue-gas thermocouples for slag build-up or sheath erosion that causes sluggish temperature feedback.
4. Flame-Safeguard 4 s Trip, Negative-Draught Switch & 220 °C Door Interlocks
MEPC.244(66) sets out the safety trips that keep an incinerator safe inside a machinery space. Under Section 5.3.2.2, the flame safeguard must shut the fuel and waste-oil valves within 4 seconds if the flame goes out while running. Under Section 5.3.2.3, an ignition attempt may last 10 seconds at most, and the fuel is cut at once if no flame forms. UV or IR flame eyes look into a hot, dusty furnace through an air-cooled sight tube, so soot on the quartz window or blocked cooling-air holes cause nuisance 4-second trips. Clean them, and never bypass them.
Unlike a pressurised auxiliary boiler, an incinerator runs with a slight vacuum in the furnace, kept by an induced-draught flue fan and a dilution damper, so flue gas and sparks cannot leak into the engine room. Under Section 5.3.1.3, a negative-pressure switch watches the draught and must raise an alarm and open the burner circuit before the furnace pressure climbs to atmospheric. Section 5.3.1.1 uses a sensor in the flue-gas duct to stop the burner when the flue gas runs hotter than the maker's set point, and Section 5.3.1.2 uses a sensor in the combustion chamber to stop it when the chamber passes its upper limit (Section 4.1 gives 1,200 °C as the top of the outlet range). Keep the induced-draught fan running through the post-purge so the unit cools evenly.
MEPC.244(66) Sections 3.10.2 and 3.12 call for interlocks on the solid-waste charging door (where there is no air-lock feeder) and on the ash-removal door, so neither can be opened during burning or while the furnace is hotter than 220 °C. Opening a hot chamber lets fresh air reach glowing char, which can flash up violently in the face of whoever is raking ash or loading bags.
Test flame-safeguard lockout during routine PMS checks by following the test method in the incinerator maker's manual (confirming fuel shut-off within 4 seconds after flame failure under 5.3.2.2 and immediate shut-off after max 10-second ignition trial under 5.3.2.3).
Prove the negative-pressure switch (MEPC.244(66) 5.3.1.3) opens the burner circuit and sounds an alarm if induced-draught suction is lost, keeping the sensing impulse line free of acidic condensate.
Confirm high flue-gas duct temperature (5.3.1.1) and high combustion chamber temperature (5.3.1.2) cutouts shut down burners cleanly while maintaining post-purge cooling air.
Verify electro-mechanical interlocks keep charging and ash-removal doors locked during firing and until furnace temperature drops below 220 °C (MEPC.244(66) 3.10.2 & 3.12).
5. SOLAS II-2 Fire Protection, Remote Stops, ISM 10.3 & MSC.581(110) Tank Entry
Incinerators bring heated waste oil, diesel pilot lines and very hot flue casings into or next to Category A machinery spaces, so SOLAS Chapter II-2 fire rules apply alongside MARPOL Annex VI. SOLAS Regulation II-2/4.2.2.6.1 (as amended by IMO Resolution MSC.99(73)) requires insulation on any surface hotter than 220 °C that oil could spray or drip onto if a fuel pipe or fitting fails, and lagging that can soak up oil must be covered so fuel cannot get in. Keep the remote shut-offs clear and tested: the quick-closing valves on oil fuel storage, settling and service tanks of 500 litres and more (SOLAS II-2/4.2.2.3.4), and the stops outside the space for machinery-space ventilation fans (SOLAS II-2/5.2.2.2) and for fuel pumps and forced or induced-draught fans (SOLAS II-2/5.2.2.3 and 5.2.2.4).
SOLAS Regulation II-2/10.5.6 applies to Category A machinery spaces over 500 m³ on passenger ships of 500 GT and over and cargo ships of 2,000 GT and over built on or after 1 July 2002, and to some older passenger ships of 2,000 GT and over under II-2/1.2.2.4. Where it applies, the incinerator is one of the high fire-risk areas that need an approved fixed water-based local system, or an approved equivalent, released both automatically and by hand on periodically unattended machinery spaces. Keep the nozzles uncapped, free of soot and aimed at the burner front and drip tray.
Under ISM Code Section 10.3, incinerator safety interlocks, emergency stops and local fire-extinguishing releases should be maintained and tested on schedule in the Planned Maintenance System. Whenever crew open a sludge tank or waste-oil settling tank for manual mucking-out or heating-coil inspection, follow the enclosed-space entry recommendations in IMO Resolution MSC.581(110) (adopted 27 June 2025, superseding A.1050(27)): isolate and blank heating steam and sludge transfer lines, ventilate thoroughly, verify steady 20.9% oxygen by volume, flammable vapours below 1% LFL, carbon dioxide below 0.5% by volume and toxic gases below 50% OEL using the portable atmosphere testing instrument with onboard calibration means required under SOLAS Regulation XI-1/7, and issue an entry permit valid for no more than 8 hours as recommended under MSC.581(110), backed by two-monthly rescue drills under SOLAS Regulation III/19.3.3. For shipowners, technical superintendents and Chief Engineers resolving chronic incinerator lockouts, refractory spalling or sludge-conditioning issues, Marvel Solutionz provides remote engineering support at $350 USD for a 1-hour consultancy (+ 5% sales tax), alongside the LNG, Dual-Fuel (DF) & Spark-Gas (SG) Academy at $395 USD self-paced (+ 5% sales tax) and Corporate Team Training for up to 10 engineers at $3,500 USD (+ 5% sales tax).
Inspect thermal insulation on flue casings and burner fronts with infrared thermography so no exposed surface above 220 °C can be impinged by fuel spray (SOLAS II-2/4.2.2.6.1).
Test external incinerator emergency fuel/power stops, waste-oil tank quick-closing valves (SOLAS II-2/4.2.2.3.4) and remote ventilation/pump stops outside the space (SOLAS II-2/5.2.2.2 to 5.2.2.4).
Where SOLAS II-2/10.5.6 applies, confirm the local fixed fire-fighting nozzles over the incinerator burner front are uncapped and the section valves are locked open.
Apply IMO Res. MSC.581(110) enclosed-space entry recommendations (20.9% O2 by volume, < 1% LFL, < 0.5% CO2 by volume, < 50% OEL, recommended max 8-hour permit, SOLAS XI-1/7 meter with calibration means) before entering any sludge tank.
6. ORB Code C Records, GRB Category E Ash & Port State Control Readiness
The Port State Control procedures in IMO Resolution A.1206(34), which replaced A.1185(33), keep the incinerator checks short. Inspectors look at whether the unit matches its IMO Type Approval Certificate, whether the maker's operating manual is on board, and whether the gas temperature at the combustion chamber outlet is monitored at all times (section 2.6.11). Under section 2.6.10 they also check that sludge is not being burned in boilers or the power plant while the ship is in port. Appendix 2 lists an incinerator that does not meet Appendix IV of MARPOL Annex VI or the MEPC.76(40) or MEPC.244(66) standard as a possible ground for detention.
Inspectors may also open the Oil Record Book, so good preparation is to keep it tidy. Every sludge burn goes in Oil Record Book Part I (MARPOL Annex I Regulation 17) under Code C, Item 12.3, with the tank, the quantity burned in cubic metres and the time taken. A quick sense check helps: the quantity divided by the hours should not be more than the incinerator can burn according to its certificate and manual, and no burn should be logged on a day when the unit was opened up for repair.
Garbage is recorded separately. Whenever solid garbage or oily rags are burned, the start and stop times, the ship's position and the cubic metres burned go in Garbage Record Book Part I (MARPOL Annex V Regulation 10, kept on paper or in an Administration-approved electronic record book under IMO Resolution MEPC.312(74)). The ash left over is Category E (incinerator ashes) under MEPC.277(70). Under MARPOL Annex V it may not be put into the sea anywhere, including outside Special Areas, so keep it on board, for example in labelled metal drums, and land it to a port reception facility. Keep the receipts on board for at least 2 years with the Garbage Record Book (the Oil Record Book Part I is kept for 3 years after its last entry). These two books record different things, so there is no figure that should balance between them.
Good preparation: check that the ORB Part I Code C Item 12.3 quantities and burning hours make sense against the incinerator's rated capacity.
Log every solid-waste incineration run with start/stop UTC and positions in GRB Part I and transfer cold ash (< 220 °C) into labelled Category E drums.
Never discharge Category E incinerator ash to sea, and land all ash to port reception facilities with receipts filed alongside the Garbage Record Book for at least 2 years (MARPOL Annex V Reg. 3 & Reg. 10).
Keep a clean burner drip tray, working local gauges, the Type Approval Certificate (IAPP Supplement Section 2.5), the maker's manual and the PMS interlock test records ready for a Port State Control inspection under A.1206(34).
Frequently Asked Questions
Why does MARPOL Annex VI Regulation 16.9 block continuous waste feeding below 850 °C?
Regulation 16.9 and MEPC.244(66) set 850 °C at the combustion chamber outlet as the lowest temperature at which a continuous-feed incinerator may take waste. Below that, burning is incomplete, so you get heavy soot, unburnt hydrocarbon vapour and more toxic emissions. A batch-loaded unit must be built to reach 600 °C in under 5 minutes from start-up and then hold at 850 °C or more (Section 4.1 gives 850 °C to 1,200 °C as the working range).
What causes repeated negative-draught alarms and trips on a marine incinerator?
Under IMO Resolution MEPC.244(66) Section 5.3.1.3, a negative-pressure switch raises an alarm and opens the burner circuit before the furnace pressure climbs to atmospheric, so flue gas and flame cannot blow back into the engine room. Frequent trips usually come from soot-fouled flue uptakes or spark arresters, slipping induced-draught fan belts, sticking dilution dampers, or condensate blocking the switch's sensing tube.
How do the high-temperature burner cutouts and the 220 °C door interlock differ under MEPC.244(66)?
Under MEPC.244(66), Section 5.3.1.1 uses a sensor in the flue-gas duct to stop the burner when the flue gas runs hotter than the maker's set point, and Section 5.3.1.2 uses a sensor in the combustion chamber to stop it when the chamber passes its upper limit (Section 4.1 gives 1,200 °C as the top of the outlet range). The induced-draught fan keeps running to cool the unit. The door interlocks are separate: under Sections 3.10.2 and 3.12, the charging door (where there is no air lock) and the ash-removal door stay locked during burning and until the furnace is below 220 °C, to prevent flashback and burns.
Can crew burn PVCs, scrubber residues or engine-room sludge while in port?
It depends on what is burned and where. MARPOL Annex VI Regulation 16.2 bans burning scrubber (EGCS) residues anywhere, along with cargo residues, PCBs, garbage with heavy metals beyond trace amounts, halogenated refined petroleum products and sludge not produced on board. Regulation 16.3 allows PVCs to be burned only in an incinerator that holds an IMO Type Approval Certificate. Regulation 16.4 stops sewage sludge and sludge oil being burned in boilers or the ship's main or auxiliary power plant inside ports, harbours and estuaries. It does not ban a type-approved incinerator in port, but port and coastal State rules may, so check the local rules before burning anything alongside.
How should sludge burning and incinerator ash be recorded in the ORB and GRB?
They go in two separate books, and they are not meant to balance against each other: cubic metres of sludge burned and cubic metres of ash left over measure different things. Sludge burned in the incinerator goes in Oil Record Book Part I under Code C, Item 12.3, with the tank, the quantity and the time taken (the book is kept for 3 years after its last entry under MARPOL Annex I Regulation 17). Garbage burned and the ash it leaves go in Garbage Record Book Part I, on paper or in an approved electronic record book under MEPC.312(74). Incinerator ash is Category E under IMO Resolution MEPC.277(70), may never go over the side, and is landed ashore with the receipts kept for at least 2 years.
What does Port State Control check at the incinerator under IMO Resolution A.1206(34)?
A.1206(34) points inspectors to a few things: the unit matches its IMO Type Approval Certificate (listed in Section 2.5 of the IAPP Supplement), the maker's operating manual is on board, the gas temperature at the combustion chamber outlet is monitored at all times, and sludge is not burned in boilers while in port. An incinerator that does not meet its type-approval standard can lead to detention under Appendix 2. Good preparation goes further: have recent PMS records of your own tests of the 220 °C door interlocks, the flue insulation (SOLAS II-2/4.2.2.6.1), the local fire-fighting nozzles where SOLAS II-2/10.5.6 applies and the emergency stops, and make sure the ORB Code C entries look sensible.
Try the LNG, Dual-Fuel & Spark-Gas simulator free for 5 minutes, then enrol in the Academy: Self-Paced $395 USD or 6-Week Cohort $995 USD (+ 5% sales tax). Or book a 1-hour consultancy for $350 USD (+ 5% sales tax).
Enquiries welcome at any time. Book our daily 1-hour consultation at 12:00 PM Central Time (CT) ($350 USD + 5% sales tax) or send an enquiry about your vessel, power plant or project.
Have an Academy Access Key? Sign in on this page to send comments or questions straight to our instructors.
/guides/shipboard-incinerator-sludge-burning-and-flue-gas-interlock-guide/